Detailed Product Description
Heat-resistance Fire-proof Cable
Enterprise standard. Fire-proof feature test refers to GB/T19216.21-2003 (equal to IEC60331).
It is used for signal checking and power transmission at high temp, rated A.C. voltage 0.6/1kV and below. Especially used for transmission line.
|
Type
|
Designation
|
|
NHFF
|
Cu core fire-proof & insulation layer heat-resistance fire-proof cable
|
|
NHFF22
|
Cu core fire-proof & insulation layer steel tape armored heat-resistance fire-proof cable
|
|
NHFF32
|
Cu core fire-proof & insulation layer steel wire armored heat-resistance fire-proof cable
|
|
NHFPF
|
Cu core fire-proof & insulation layer heat-resistance shield fire-proof cable
|
|
NHFPF22
|
Cu core fire-proof & insulation layer steel tape armored heat-resistance shield fire-proof cable
|
|
NHFPF32
|
Cu core fire-proof & insulation layer steel wire armored heat-resistance shield fire-proof cable
|
Conductor type
Armoring material
Sheath material
Shielding material
Insulating material
Series code
|
Item
|
Unit
|
Technical performances
|
|
D.C. Resistance of conductor (20)≤
|
Ω/km
|
mm2 section
|
0.5
|
0.75
|
1.0
|
1.5
|
2.5
|
4
|
6
|
10
|
16
|
25
|
35
|
50
|
70
|
95
|
120
|
|
Resis-tance
|
36
|
24.5
|
18.1
|
12.1
|
7.4
|
4.61
|
3.08
|
1.83
|
1.15
|
0.727
|
0.524
|
0.387
|
0.268
|
0.193
|
0.153
|
|
Test voltage
|
kV/1min
|
450/750V Test Voltage 2.5KV
600/1000V Test Voltage 3.5KV
|
|
Insulation resistance≥
|
MΩ·km
|
100
|
|
Fire-resistance feature
|
|
Grade A (Flame temp 1000℃ 90min test 3A fuse wire not break)
|
|
Item
|
Code
|
Explanation
|
|
Series code
|
NH
|
Fire-proof cable
|
|
Insulating material
|
F
|
Fire-proof insulating material
|
|
Shielding material
|
/
P
|
No shield to be omitted
Tin-plated woven Cu wire
|
|
Sheath material
|
F
|
(F46) F46
|
|
Armoring material
|
22
32
|
Steel tape armored
Thin steel wire armored
|
|
Conductor type (fill in the brackets)
|
A
B
|
Single strand conductor
Twisted conductor
|
E.G.1: Five core1.0mm2 type A conductor heat-resistance fire-proof cable is described as: NHFF 5×1.0(A)
E.G.2: Five core 120mm2 Cu conductor steel wire armored Tin-plated woven Cu wire shield heat-resistance fire-proof cable is described as:NHFPF22 5×120
-
Application characteristics
-
Operating temp: Long time use 200℃, short time use 1000℃ 90 minutes.
-
Rated voltage U0/U: 450/750V, 600/1000V
-
Min. ambient temp: fixed installation -60℃, non-fix installation -20℃.
-
Min. bending radius: Non-armored cable≥10 times the cable outer dia.
Armored cable ≥12 times the cable outer dia.
|
Type
|
Nominal cross section mm2
|
|
0.5
|
0.75
|
1.0
|
1.5
|
2.5
|
4
|
6
|
10
|
16
|
25
|
35
|
50
|
70
|
95
|
120
|
|
Core number
|
|
NHFF
|
2~61
|
2~10
|
1~5
|
|
NHFF22
|
—
|
4~61
|
2~10
|
2~5
|
|
NHFF32
|
—
|
4~61
|
4~10
|
3~5
|
|
NHFPF
|
2~61
|
2~10
|
1~5
|
|
NHFPF22
|
—
|
4~61
|
2~10
|
2~5
|
|
NHFPF32
|
—
|
4~61
|
4~10
|
3~5
|
Non-armored cable is 500m armored cable is 200m, shortage length more than 30m may be delivered but not exceed 10% of the total length delivered special requirement to be discussed between the supplier and the buyer.