- I'm Online Chat Now
No Halogen Fire Retardant Fire Resisting Power Cable
-

-
Large Image : No Halogen Fire Retardant Fire Resisting Power Cable
Product Details:
| Place of Origin: | Hebei,china(Mainland) |
|---|---|
| Brand Name: | New Baofeng |
Payment & Shipping Terms:
| Minimum Order Quantity: | 500 Meter/MetersTrial Order |
|---|---|
| Price: | Negotiable |
| Packaging Details: | Wooden drums with iron frame |
| Delivery Time: | Negotiable |
| Payment Terms: | L/C,T/T |

No Halogen Fire Retardant Fire Resisting Power Cable
■ Product standard
Enterprise standard
■ Application
This product is suitable for AC 0.6/1kV of power frequency or below equipment, fire hazard and fire fighting equipment, emergency passage transportation, lighting, etc emergency facilities where the power supply requires fireproof fields. Particularly it is suitable for subway, under-ground shop, high-rise, intelligence communication building, power station and so on fields with high safe requirements.
■ Product characteristics
1. With all characteristics of no halogen low smoke fire retardant power cable.
2. Burn at 800℃ and below flame environment, can guarantee to electrify over 180 min. compared with ordinary cable, its time of fireproof can prolong two times, the safety is better.
■ Type and Specifications
|
Type |
No. of Core |
Nom. area Cross-Section area mm2 |
|
WDZN-YJY WDZN-YJY23 WDZN-YJY33 |
1 |
2.5~1000 |
|
2,3,4,5 |
4~240 |
|
|
Note: When 1-core cable needs to armor, the cross section should not be less than 10mm2. Meanwhile it should use non-magnetic material or reduce magnetic loss structure. |
||
|
Type |
Designation |
|
WDZN-YJY |
Copper-conductor XLPE insulated PO sheathed no halogen low smoke fire retardant fire resisting power cable |
|
WDZN-YJY23 |
Copper-conductor XLPE insulated steel tape armored PO sheathed no halogen low smoke fire retardant fire resisting power cable |
|
WDZN-YJY33 |
Copper-conductor XLPE insulated fine steel wire armored PO sheathed no halogen low smoke fire retardant fire resisting power cable |
■ Construction
1. Conductor
2. Fire-resisting insulation layer
3. XLPE insulation
4. Insulation
5. Inner covering
6. Armor
7. Oversheath
■ Main performance
1. Combustion property
(1) Halogen gases releasing amount test, pH value≥4.3,electrical conductivity≤10ms/mm
(2) Cable combustion smoking amount test, light transmittance≥60%
(3) Cable fireproof test: pass B kind fireproof test specified in IEC6033 and GB12666.6
(4) Cable fire retardant test: pass bundling(or B kind or C kind)combustion test specified in IEC 60332 and GB12666.5
2. Electric property
(1) D.C. conductor resistance complies with the stipulations of the nether table;
(2) Working frequency voltage test for cable with 3500V/5min without puncture.
(3) Constant of insulation resistance at 90℃ should not more than 3.67 MΩ·Km.
|
Nominal Cross-sectional area mm2 |
Max. resistance of copper conductor (20℃) |
|
2.5 |
7.41 |
|
4 |
4.61 |
|
6 |
3.08 |
|
10 |
1.83 |
|
16 |
1.15 |
|
25 |
0.727 |
|
35 |
0.524 |
|
50 |
0.387 |
|
70 |
0.268 |
|
95 |
0.193 |
|
120 |
0.153 |
|
150 |
0.124 |
|
185 |
0.0991 |
|
240 |
0.0754 |
3. Approximate diameter and weight of cable
|
WDZN-YJY |
|||||||||
|
Nominal Cross-sectional area mm2 |
Approximate diameter mm
|
Approximate weight kg/km |
|||||||
|
Main mm2 |
Earth mm2 |
No. of Core |
Copper core |
||||||
|
1 |
2 |
3 |
4 |
1 |
2 |
3 |
4 |
||
|
2.5 |
— |
— |
— |
18.0 |
18.5 |
— |
— |
371 |
501 |
|
4 |
— |
12.4 |
19.1 |
19.3 |
19.9 |
165 |
373 |
445 |
597 |
|
6 |
— |
12.9 |
20.2 |
20.4 |
21.1 |
196 |
435 |
531 |
710 |
|
10 |
— |
13.9 |
22.2 |
22.6 |
23.6 |
255 |
577 |
703 |
947 |
|
16 |
— |
14.9 |
24.2 |
24.7 |
26.8 |
331 |
694 |
930 |
1308 |
|
25 |
— |
16.5 |
28.1 |
28.8 |
31.5 |
450 |
1060 |
1368 |
1938 |
|
35 |
— |
17.5 |
30.1 |
31.0 |
34.2 |
564 |
1279 |
1726 |
2460 |
|
50 |
— |
19.1 |
28.4 |
30.4 |
34.6 |
740 |
1594 |
2186 |
3055 |
|
70 |
— |
20.7 |
32.8 |
33.8 |
38.8 |
965 |
2156 |
2928 |
4014 |
|
95 |
— |
22.5 |
35.1 |
38.0 |
44.5 |
1232 |
2715 |
3820 |
5295 |
|
120 |
— |
25.2 |
37.6 |
41.7 |
49.5 |
1527 |
3314 |
4710 |
6526 |
|
150 |
— |
27.2 |
41.9 |
47.7 |
55.7 |
1904 |
4083 |
5932 |
8110 |
|
185 |
— |
30.4 |
57.4 |
51.8 |
59.6 |
2380 |
5593 |
7132 |
9730 |
|
240 |
— |
33.2 |
63.0 |
60.9 |
62.74 |
2986 |
6941 |
9239 |
12037 |
|
Nominal Cross-sectional area mm2 |
Approximate diameter mm |
Approximate weight kg/km |
|||||||
|
Main mm2 |
Earth mm2 |
No. of Core |
Copper core |
||||||
|
5 |
3+1 |
3+2 |
4+1 |
5 |
3+1 |
3+2 |
4+1 |
||
|
2.5 |
— |
18.8 |
— |
— |
— |
431 |
— |
— |
— |
|
4 |
2.5 |
20.1 |
20.7 |
21.5 |
222 |
566 |
435 |
477 |
521 |
|
6 |
4 |
21.4 |
21.8 |
27.2 |
27.8 |
702 |
539 |
708 |
745 |
|
10 |
6 |
25.7 |
25.6 |
31.5 |
32.6 |
1039 |
792 |
1021 |
1095 |
|
16 |
10 |
28.6 |
28.0 |
35.6 |
36.5 |
1433 |
1067 |
1369 |
1481 |
|
25 |
16 |
34.5 |
33.0 |
41.3 |
43.9 |
2150 |
1563 |
1880 |
2263 |
|
35 |
16 |
38.1 |
35.8 |
44.8 |
47.2 |
2813 |
1902 |
2634 |
2732 |
|
50 |
25 |
41.5 |
37.6 |
41.9 |
45.7 |
3689 |
2751 |
3415 |
3912 |
|
70 |
35 |
47.5 |
41.1 |
47.1 |
49.7 |
5026 |
3579 |
4503 |
4937 |
|
95 |
50 |
52.7 |
47.6 |
52.8 |
55.8 |
6504 |
4730 |
5704 |
6507 |
|
120 |
70 |
59.3 |
51.1 |
58.5 |
59.4 |
8209 |
5873 |
7327 |
7925 |
|
150 |
70 |
64.8 |
56.7 |
62.3 |
65.4 |
10077 |
7005 |
8306 |
9395 |
|
185 |
95 |
71.2 |
61.8 |
68.6 |
71.4 |
12233 |
8463 |
10220 |
11336 |
|
240 |
120 |
78.7 |
68.2 |
75.7 |
78.9 |
15412 |
10679 |
12659 |
14122 |
|
WDZN-YJY23,WDZN-YJY33 |
|||||||||
|
Nominal Cross-sectional area mm2 |
Approximate diameter mm |
Approximate weight kg/km |
|||||||
|
Main mm2 |
Earth mm2 |
No. of Core |
Copper core |
||||||
|
1 |
2 |
3 |
4 |
1 |
2 |
3 |
4 |
||
|
2.5 |
— |
— |
— |
20.8 |
22.1 |
— |
— |
754 |
886 |
|
4 |
— |
15.8 |
22.7 |
22.1 |
23.5 |
— |
479 |
990 |
1027 |
|
6 |
— |
16.3 |
23.7 |
24.0 |
24.7 |
— |
556 |
1012 |
1188 |
|
10 |
— |
17.6 |
26.3 |
26.2 |
27.1 |
488 |
669 |
1238 |
1495 |
|
16 |
— |
18.6 |
29.2 |
28.3 |
30.3 |
612 |
879 |
1528 |
1924 |
|
25 |
— |
20.3 |
32.8 |
32.7 |
35.0 |
763 |
1251 |
2056 |
2631 |
|
35 |
— |
21.5 |
36.9 |
34.8 |
337.9 |
898 |
1528 |
2468 |
3196 |
|
50 |
— |
22.9 |
33.9 |
34.4 |
38.4 |
1109 |
1807 |
2977 |
3858 |
|
70 |
— |
22.9 |
38.0 |
37.8 |
42.6 |
1358 |
2403 |
3785 |
4920 |
|
95 |
— |
24.3 |
41.7 |
41.8 |
48.5 |
1662 |
2979 |
4767 |
6355 |
|
120 |
— |
27.4 |
43.9 |
45.5 |
53.7 |
2245 |
3617 |
5743 |
7732 |
|
150 |
— |
28.5 |
48.7 |
51.8 |
60.1 |
2630 |
4442 |
7119 |
9486 |
|
185 |
— |
30.4 |
61.7 |
56.2 |
64.1 |
3183 |
6148 |
8359 |
11240 |
|
240 |
— |
36.8 |
67.4 |
65.8 |
67.7 |
3864 |
7567 |
10788 |
13704 |
|
Nominal Cross-sectional area mm2 |
Approximate diameter mm |
Approximate weight kg/km |
|||||||
|
Main mm2 |
Earth mm2 |
No. of Core |
Copper core |
||||||
|
5 |
3+1 |
3+2 |
4+1 |
5 |
3+1 |
3+2 |
4+1 |
||
|
2.5 |
— |
20.5 |
— |
— |
— |
778 |
— |
— |
— |
|
4 |
2.5 |
21.6 |
23.0 |
23.8 |
27.3 |
921 |
729 |
768 |
839 |
|
6 |
4 |
22.9 |
24.1 |
29.6 |
33.1 |
1085 |
853 |
1001 |
1167 |
|
10 |
6 |
25.0 |
27.9 |
34.1 |
38.1 |
1487 |
1174 |
1356 |
1848 |
|
16 |
10 |
29.3 |
31.3 |
38.9 |
42.0 |
1942 |
1709 |
1946 |
2329 |
|
25 |
16 |
32.4 |
36.5 |
44.9 |
49.7 |
2750 |
2330 |
2582 |
3214 |
|
35 |
16 |
38.3 |
39.1 |
48.4 |
54.1 |
3468 |
2750 |
3425 |
3812 |
|
50 |
25 |
41.9 |
40.9 |
45.5 |
49.4 |
4762 |
3519 |
4323 |
4956 |
|
70 |
35 |
45.7 |
44.6 |
50.8 |
53.5 |
6263 |
4436 |
5542 |
6086 |
|
95 |
50 |
51.7 |
51.3 |
56.7 |
59.7 |
7882 |
5678 |
6918 |
7758 |
|
120 |
70 |
57.1 |
54.8 |
62.7 |
63.6 |
9783 |
6967 |
8691 |
9352 |
|
150 |
70 |
63.9 |
61.1 |
66.7 |
69.4 |
11839 |
8247 |
9792 |
10953 |
|
185 |
95 |
69.9 |
65.9 |
73.2 |
76.0 |
14218 |
9832 |
11952 |
13098 |
|
240 |
120 |
76.2 |
72.7 |
80.6 |
85.2 |
17740 |
12218 |
14454 |
17104 |
■ Operating characteristics
1. The Max. rated temperature of conductor is 90℃.
2. Max. short-circuit temperature of conductor shall not exceed 250℃(5s max. duration)
3. The Min. ambient temperature of cable laying is 0℃
4. The Min. bending radius of cable: Single-core cable is 20 times of cable diameter; Multi-core cable is 15 times of cable diameter.
■ Delivery lengths
The delivery length is not less than 100m, delivered special requirement to be discussed between the supplier and the buyer, the tolerance of length shall not exceed in ±0.5%.
- Other Products
- XLPE Insulated No Halogen Low Smoke Fire Retardant Power Cable
- medium voltage 450 / 750v XLPE Insulated Electrical power Cable with fire proof material
- XLPE Insulated Dust Filter Power Cable For Rated Voltage DC 75Kv
- Rated Voltage Including 35kV Mouse Resistant, Ant Resistant, UV Lay Resistant Power Cable
- One Step Method Silane XL Cable
- XLPE insulated Control Cable For Ship