Hebei New Baofeng Wire & Cable Co.,Ltd

Sales & Support
Request A Quote - Email
Select Language
English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
HomeProductsLow-voltage power cable

Prefabricated Waterproof and Refractory branch cable

China  good quality  High voltage cable on sales
China  good quality  High voltage cable on sales
I'm Online Chat Now

Prefabricated Waterproof and Refractory branch cable

Large Image : Prefabricated Waterproof and Refractory branch cable

Product Details:

Place of Origin:Hebei,china(Mainland)
Brand Name:New Baofeng

Payment & Shipping Terms:

Minimum Order Quantity:500 Meter/MetersTrial Order
Price:Negotiable
Packaging Details:Wooden drums with iron frame
Delivery Time:Negotiable
Payment Terms:L/C,T/T
Detailed Product Description

 

Branch Cable

■ Product standard

JG/T147-2002 and Enterprise standard

 Description products

In the recent years, with the development of our national economy and basic establishment, more middle buildings, high buildings and super high buildings distribution have been built up. Owing to the increase of the complexity and capacity of distribution among modern buildings, stability and economic requirement to mainline of distribution are getting higher and higher. In order to satisfy the market requirement, we consulted international and national relevant information, and under the direction of relative expert, we researched and developed branch cable (pre-made branch cable).The product was tested by the authorization dept. of national wire & cable -National quality supervising & testing center for cable and wire and antiflame construction material. All the technical functions are up to the enterprise standard requirements.The main function exceed JCS376 Japan Standard Requirement of “With Branch Cable”. It is mainly suitable for power supply units and controller switching equipment transmitting electricity with 1000V rated voltage and below in middle and high building, industrial and mining unit, enterprise unit and institution. The product has the advantages of safe and reliable power supply, excellent insulating performance, convenient construction and installation, low cost of distribution, wide application scope, wide arrange of varieties and specification, and low requirements of installation environment. In foreign advanced countries, cable with branch has been widely applied to replace the transmission method of bus slots. Compared with bus slots, the product has the additional functions of anti-vibration, water proofing, and flame-resistance, which avoid troubles of installation and maintenance of bus slots.

■ Merits of Prefabricated Branch Cable

1. The product possesses fine power supply reliability

 (1) There is no joint on main cable’s conductor, so it has a good continuity while fault points being reduced.

 (2) The joints of prefabricated branch cable have been manufactured by whole factory-used mechanical equipment so that the instability caused by human factor will be greatly reduced.

 (3) The Japanese advanced technology has been introduced for designing branch joint structure, the contact resistance of it is very small and never be influenced by heat expansion or cold shrinkage.

 (4) The branch joint is shaped in a short time, so changes of contact resistance, caused by oxidation because the conductor being exposed in the open air for a long time, can be completely avoided.

2. Electric Distribution Cost Being Obviously Reduced

(1)As compared with bus-bar groove, it can reduce the engineering cost while its technical and economic targets are so high and comprehensive economic benefits are obvious.

3. Various Specifications, Flexible Selection and Free Combination

 (1) Main cable from 10mm2 to 630mm2; branch cable from 6mm2 to 400mm2, freely combined.

 (2) A variety of cables, such as FZ-VV, FZ-ZR-VV, FZ-NH-VV, FZ-YJV, FZ-ZR-YJV, FZ-NH-YJV, FZ-WDZ-YJE, FZ-DL-NH-YJV etc, all of them can be selected according to different requirements.

 (3) Branch cable can be installed in the light of building conditions.

4. Low Environment Requirements for Installation, Easy for Construction

 (1) Occupying a small area, the product is nice for the effective use of construction area, while it needs only a limited space in construction.

 (2) Both its requirements for environment conditions and installation precision are very common.

 (3) It can be installed easily and one winder is enough for installation; and its installation period is also very short, it only needs 5%-10% installation hours of that of bus-bar groove, with low labor strength.

 (4) Due to its bending radius is small, the installation difficulties of such product will be greatly reduced, and the occupied space is also small.

5. Excellent Vibration Resistance, Air-Tightness, Waterproof and Refractory

 (1) Fine Vibration resistance: When the joint of bus-bar groove is connected with machinery, looseness of especially, no measures should be adopted when the cable passes the settlement joint of building.

 (2) Fine air-tightness and waterproof: the product can work normally in a wet circumstance and also can be laid in the open air or underground.

 (3) “NH” type of prefabricated branch cable is adopted, so 90 min of normal power supply still can be kept under firing.

6. No Maintenance

 (1) If the prefabricated branch cable is correctly installed following the relative requirements, its one-time cutting-in function is effective.

 (2) The normally operated prefabricated branch cable is no necessary to make any maintenance.

■ Type and Name of Cable

Type

Designation

FZ-VV

Copper conductor PVC insulated and sheathed prefabricated branch cable.

FZ-ZR-VV

Copper conductor PVC insulated and sheathed flame-retardant prefabricated branch cable

FZ-NH-VV

Copper conductor PVC insulated and sheathed fire resisting prefabricated branch cable

FZ-YJV

Copper conductor XLPE insulated and PVC sheathed prefabricated branch cable

FZ-ZR-YJV

Copper conductor XLPE insulated and PVC sheathed flame-retardant prefabricated branch cable

FZ-NH-YJV

Copper conductor XLPE insulated and PVC sheathed fire resisting prefabricated branch cable

FZ-WDZ-YJE

Copper conductor XLPE insulated and polyolefine sheathed low-fume-no-halogen flame-retardant prefabricated branch cable

FZ-DL-NH-YJE

Copper conductor XLPE insulated and polyolefine sheathed low-fume-no-halogen fire-resisting prefabricated branch cable

FZ-N-VV

Copper conductor PVC insulated and sheathed stranded prefabricated branch cable

FZ-N-ZR-VV

Copper conductor PVC insulated and sheathed flame-retardant stranded prefabricated branch cable

FZ-N-NH-VV

Copper conductor PVC insulated and sheathed fire-resisting stranded and prefabricated branch cable

FZ-N-YJV

Copper conductor XLPE insulated and sheathed stranded prefabricated branch cable

FZ-N-ZR-YJV

Copper conductor XLPE insulated and sheathed flame-retardant stranded prefabricated branch cable

FZ-N-NH-YJV

Copper conductor XLPE insulated and sheathed fire-resisting stranded and prefabricated branch cable

FZ-N-WDZ-YJE

Copper conductor XLPE insulated polyole fine  sheathed low-fume-no-halogen stranded prefabricated branch cable

FZ-N-DL-NH-YJV

Copper conductor XLPE insulated polyole fine sheathed low-fume-no-halogen fire-resisting stranded prefabricated branch cable

 

■ Specifications of Main Cable & branch Cable of Prefabricated Branch Cable

Cross Section of Main Cable mm2

Cross Section of branch Cable mm2

10

6

10

                       

16

6

10

16

                     

25

6

10

16

25

                   

35

6

10

16

25

35

                 

50

6

10

16

25

35

50

               

70

6

10

16

25

35

50

70

             

95

6

10

16

25

35

50

70

95

           

120

6

10

16

25

35

50

70

95

120

         

150

6

10

16

25

35

50

70

95

120

150

       

185

6

10

16

25

35

50

70

95

120

150

185

     

240

6

10

16

25

35

50

70

95

120

150

185

240

   

300

6

10

16

25

35

50

70

95

120

150

185

240

300

 

400

6

10

16

25

35

50

70

95

120

150

185

240

300

400

500

6

10

16

25

35

50

70

95

120

150

185

240

300

400

630

6

10

16

25

35

50

70

95

120

150

185

240

300

400

 

 

■ Structure of Prefabricated Branch Cable

 

Main Cable mm2

 

Branch Cable mm2

Reference Size  mm

d1

d2

L

10

~10

 

 

54

 

 

35

 

 

95

16

~16

25

~25

35

~35

50

~50

 

57

 

38

 

95

70

~70

95

~95

120

~120

 

78

 

52

 

145

150

~150

185

~185

240

~240

 

96

 

70

 

160

300

~300

400

~400

500

~400

106

80

170

630

~400

Drawing of Branch Cable’s Joint

 

Both standard

 

 

 

 

 

 

maincable and line cable are insulated and sheathed with the relative materials conforming to their types and manufactured according to the IEC, GB and JCS. Usually the main cable is made with single-core or stranded multi-core (2-core to 5-core), branch cable is adopted single-core. The features of cable structure as follows.

1. Non-fire-resisting cable structure

1. Conductor        2. Insulation        3. Sheath

    2.  Structure of fire-resisting Cable

             1. Conductor           2. Fire-resisting layer

             3. Insulation            4.Sheath

3. Joint Structure of Branch Cable

   The joint of prefabricated branch cable is adopted special PVC or synthetic material, the right-sided drawing shows the joint of branch cable.

■Main Technical Properties of Prefabricated Branch Cable

No.

Items

Property Requirements

1

Insulation voltage resisting

Power frequency voltage 3.5kV, 5min, no breakdown

2

Insulation resistance

≥200MΩ

3

Resistance ratio of branch joint

Resistance ratio of branch joint kj≤1.2

4

Short-circuit test

Change ratio of D.C. Resistance after short circuit yj 0.2

5

Heat circulation test

Measured value of no.25 period: ≤75℃

Measured value of no.26-125 period, smaller than measured value ±8℃ of temperature rise of no.25 period

6

Flame-retarding

Automatic firing blanked off: within 15 seconds

7

Metal tool lifting

Tensile force

24h, double weight no tracking out

Insulating voltage

Work frequency 3.5kV, 5min, not breakdown

Insulating resistance

≥200MΩ

8

Molding plastic

Original property

Tensile force

≥10MPa

Extensibility

≥120%

Property of airbox when ageing

Tensile force

≥8.5MPa

Extensibility

≥95%

Property after test for temperature resisting

Tensile force

≥8.5MPa

Extensibility

≥95%

Cold-proof

Non-fracture

Deform when heating

Extenuation ratio of thickness not over 50%

■ Structure Parameter & Electricity Property of 0.6/1kV Single-Core XLPE Insulated Prefabricated Branch Cable.

(Also suiting for the prefabricated branch cable of flame-retarding, fire-resisting, low-halogen, low-fume and

no-halogen)

 

 

Conductor

Nominal Insulation thickness mm

Nominal Thickness of nylon sheath mm

Calculated Diameter of Cable  mm

Calculated Weight of Cable kg/km

A.C. Voltage Test kV/5min

Max. D.C. resistance of conductor (20℃) Ω/km

Reference current carrying capacity (40℃) (A)

Voltage Drop V/A. m

Area of Nominal cross-section mm2

Form & Structure No./mm

Diameter (Reference Value) mm

10

Round

Densified

Cross

4.05

0.7

1.4

9.0

150

3.5

1.3

93

0.002

16

5.1

0.7

1.4

9.5

210

3.5

1.15

120

0.0013

25

6.0

0.9

1.4

11.0

310

3.5

0.727

155

0.00084

35

7.0

0.9

1.4

12.0

410

3.5

0.524

195

0.00063

50

8.3

1.0

1.4

14.0

555

3.5

0.387

235

0.00049

70

10.0

1.1

1.4

15.0

760

3.5

0.268

295

0.00036

95

11.6

1.1

1.4

17.0

1020

3.5

0.193

370

0.00029

120

13.0

1.2

1.6

19.0

1260

3.5

0.153

430

0.00024

150

14.6

1.4

1.6

21.0

1570

3.5

0.124

495

0.00021

185

16.2

1.6

1.6

23.0

1920

3.5

0.0991

570

0.00019

240

18.4

1.7

1.7

26.0

2470

3.5

0.0754

680

0.00016

300

20.6

1.8

1.8

29.0

3090

3.5

0.0601

790

0.00015

400

23.8

2.0

1.9

32.0

4080

3.5

0.0470

920

0.000131

500

26.6

2.2

2.0

36.0

5080

3.5

0.0366

1080

0.00012

630

30.0

2.4

2.2

40.0

6390

3.5

0.0283

1260

0.000111

Conductor

Nominal Insulation thickness mm

Nominal Thickness of nylon sheath mm

Calculated Diameter of Cable  mm

Calculated Weight of Cable kg/km

A.C. Voltage Test kV/5min

Max. D.C. resistance of conductor

 (20℃) Ω/km

Reference current carrying capacity (40℃)

(A)

Voltage Drop

V/A. m

Area of Nominal cross-section mm2

Form & Structure No./mm

Diameter (Reference Value) mm

10

Round

Densified

Cross

4.05

1.0

1.4

9.0

150

3.5

1.83

70

0.002

16

5.1

1.0

1.4

10.0

215

3.5

1.15

97

0.0013

25

6.0

1.2

1.4

11.3

310

3.5

0.727

120

0.00084

35

7.0

1.2

1.4

12.3

410

3.5

0.524

150

0.00063

50

8.3

1.4

1.4

14.0

570

3.5

0.387

180

0.00049

70

10.0

1.4

1.4

15.7

770

3.5

0.268

230

0.00036

95

11.6

1.6

1.7

18.4

1030

3.5

0.193

280

0.00029

120

13.0

1.6

1.7

19.8

1280

3.5

0.153

325

0.00024

150

14.6

1.8

1.8

22.8

1590

3.5

0.124

375

0.00021

185

16.2

2.0

1.8

25.1

1950

3.5

0.0991

430

0.00019

240

18.4

2.2

1.8

28.5

2490

3.5

0.0754

515

0.00016

300

20.6

2.4

2.1

32.0

3140

3.5

0.0601

595

0.00015

400

23.8

2.6

2.2

35.4

4140

3.5

0.0470

700

0.000131

500

26.6

2.8

2.3

40.0

5140

3.5

0.0366

810

0.00012

630

30.0

2.8

2.4

46.0

6440

3.5

0.0283

950

0.000111

Note:The interval between two cables for flat laying is 2-fold of cable’s diameter.

■ Structure Parameter & Electricity Property of 0.6/1kV Single-Core PVC Insulated Prefabricated Branch Cable. (Also suiting for branch cable of flame-retarding and fire-resisting type)

                                     Note: The interval between two cables for flat laying is 2-fold of cable’s diameter.

 

■ Structure Parameter & Electricity Property of 0.6/1kV Four-Core Stranded Type Cross-Linking Polythene Insulating & Prefabricated Branch Cable.

(Also suiting for the prefabricated branch cable of flame-retarding, fire-resisting, low-halogen, low-fume and no-halogen)

Conductor

Nominal Insulation thickness mm

Nominal Thickness of nylon sheath mm

Calculated Diameter of Cable  mm

Calculated Weight of Cable kg/km

A.C. Voltage Test kV/5min

Max. D.C. resistance of conductor

 (20℃) Ω/km

Reference current carrying capacity (40℃)

(A)

Voltage Drop

V/A. m

Area of Nominal cross-section mm2

Form & Structure No./mm

Diameter (Reference Value) mm

10

Round

Densified

Cross

4.05

0.7

1.4

20.5

620

3.5

1.83

65

0.002

16

5.1

0.7

1.4

23.0

860

3.5

1.15

84

0.0013

25

6.0

0.9

1.4

26.5

1270

3.5

0.727

110

0.00084

35

7.0

0.9

1.4

29.0

1680

3.5

0.524

135

0.00063

50

10.0

1.0

1.4

33.0

2270

3.5

0.387

170

0.00049

70

10.0

1.1

1.4

36.5

3110

3.5

0.268

215

0.00036

95

11.6

1.1

1.4

41.0

4170

3.5

0.193

265

0.00029

120

13.0

1.2

1.6

46.0

5150

3.5

0.153

310

0.00024

150

14.6

1.4

1.6

51.0

6410

3.5

0.124

350

0.00021

185

16.2

1.6

1.6

55.5

7840

3.5

0.0991

405

0.00019

240

18.4

1.7

1.7

63.0

10080

3.5

0.0754

480

0.00016

300

20.6

1.8

1.8

70.0

12610

3.5

0.0601

555

0.00015

■ Correction Factor for calculating current carrying capacity

1. Correction Factor of Temperature

 

Correction

factor

Ambient

temperature ℃

 

10

 

15

 

20

 

25

 

30

 

35

 

40

 

45

 

50

 

55

 

60

In air

1.26

1.22

1.18

1.14

1.10

1.05

1.00

0.95

0.89

0.84

0.78

2. Correction Factor of Different Layings

2.1 Single-core prefabricated branch cable

Laying of single-layer                                     Laying of double-layer

 

S=2d, 4-piece parallel-laying                                S=2d, 4-piece parallel-laying

Conductor temperature 90℃                                Correction factor=0.9

Ambient temperature 40℃

 

2.2 Stranded multi-core type prefabricated branch cable

Laying of single-piece                                      Multi-piece laying

 

Conductor temperature 90℃                               S=2d, 4-piece parallel-laying

Ambient temperature 40℃                                Correction factor=0.9

 

■ Installation Requirements of Prefabricated Branch Cable

   When prefabricated branch cable is installed vertically, the following requirements should be conformed to:

1. Cable drum should be put on wire-holder (usually cable drum is put on the ground of the relative building, then it is lifted).

2. Rope used for lifting is connected with cable through winder.

3. Winder is operated for cable’s lift.

4. When net-binding used for lifting cable reaches house-top, the net-binding should be hung on a prepared hook.

5. Central part should be fixed.

6. The terminal of cable should be connected with ammeter or cutout.

7. Main cable should be connected.

■ Matters Needing Attention for Prefabricated Branch Cable When Laying

1. Confirm if prefabricated branch cable has safely passed the through-hole.

2. Adopt preventive measures so as to prevent branch parts damaged when lifting.

3. Not exert any tension on branch line in the course of lifting.

4. Rope should be used for lifting the cable with more than 4-fold weight of the cable.

5. When finishing the lift, cable should be immediately suitably fixed so as to prevent cable drop.

■ Illustrated Instructions for Installing Prefabricated Branch Cable

■ Treatment for Prefabricated Branch Cable’s Top Part

   A PVC cap should be covered on each main cable so as to prevent water and the cover-cap is strengthened with heat shrinkable tube for permanent use.

■ Requirements for Ordering Prefabricated Branch Cable

The following materials should be provided when placing orders:

1. System diagram, power of distribution system and method of electricity distribution.

2. Types, specifications and length of main cables.

3. Types, specifications and length of branch cables.

4. When laying, see if cable is pulled from ground or pulled from the top of building.

5. Whether the terminal of cable should be treated or not.

6. Names, types, specifications and quantity of other accessories.

7. Engineering Diagram should be provided.

 

 

Contact Details
Hebei New Baofeng Wire & Cable Co.,Ltd

Contact Person: Mrs.Yi Shen

Tel:86-10-59361676

Fax:86-10-59361677

Send your inquiry directly to us (0 / 3000)

Other Products
XLPE Insulated Electrical Cable For Rated Voltage 0.6/1kV
low - voltage power prefabricated branch cable power supply reliability 10mm2 to 630mm2
Copper conductor 90℃ PVC insulated nylon sheathed wire low - voltage power cable 300V 500V
low - voltage power PVC insulated fixed laying cable wire for construction, electrical
Aluminum Coppe conductor,PE PVC sheathed Electrical low - voltage power cable for tunnel
High quality PVC insulated fixed laying cable wire