Detailed Product Description
■ Product standard
GB1170-74,MT386
■ Application
The flexible rubber-sheathed soft cable for mining purposes is made for the application in various movable electrical
appliance and excavators in mine.
■ Specifications and Names
|
Type
|
Designation
|
Application
|
|
UZ
|
Drill cables
|
For drills under well at rated A.C.rated
voltage up to and including 0.5KV
|
|
U
|
Movable rubber-sheathed flexible cables for mining purposes
|
For various movable electrical appliances
under well at rated A.C.voltage up to
and including 1KV
|
|
UP
|
Movable rubber-sheathed flexible cables with screen for
mining purposes
|
For various movable electrical appliances
under well
at ated A.C. voltage up to and including 1KV
|
|
UC
|
Rubber-sheathed Flexible coalcutter cables
|
For coal cutters and excavators under well at
rated A.C. voltage up to and including 1KV
|
|
UCP
|
Rubber-sheathed Flexible coalcutter cables with screens
|
For coal cutters and excavators under well at
rated A.C. voltage up to and including 1KV
|
■ Produce range of cable
|
Type
|
Voltage grade
|
Nominal cross sectional area
of main core mm
|
No. of cores
|
|
Main core
|
Earthing core
|
Control core
|
|
UZ
|
0.5
|
2.5, 4
|
3
3
|
1
1
|
0
1
|
|
U
UP
|
1
|
4
|
3
3
|
1
1
|
0
1
|
|
6-70
|
3
|
1
|
0
|
|
UC
UCP
|
1
|
10
|
3
|
1
|
2
0
|
|
16
|
3
|
1
|
3
0
|
|
25-35
|
3
|
1
|
4
0
|
|
50
|
3
|
1
|
7
0
|
■ Technical Data
1. When the temperature is at +20℃, the DC resistance of wire core of finished cable should be in conformity with the regulations of GB/T3956.
2. When the temperature is at +20℃, the insulation resistance at the insulation core surface of UZ type cable should be less than 100M per 1km. When the temperature is at +20℃,the insulation resistance between the space of insulation wires of U,UP,UCP type cable should be less than 100M per 1km.
3. The space between the control wire cores of UZ type cable, UC and UCP type cable should withstand AC 50Hz, 2000V voltage test for 5 min mutes. The space between the wire cores of U, UP, UC and UCP type cable should withstand AC 50Hz, 3000V voltage test for 5minutes.
4. When the cross section of U,UP,UC,and UCP cable is 16 mm2 or more, it should possess mechanical compact and compressive property.
5. The standard sheath cable for mine should meet relative regulations of MT386.